Gas-fire Burner
Gas / Oil fired high velocity portable combusion system are used for Post Weld Heat Treatment, Refractory Dryouts and curing. The Oil / Gas high velocity burner systems provide from 5,00,000 kcal/hr up to 8,000,000 Kcal/hr ( 2000,000 Btu/hr to 32,000,000 Btu/hr ).The unit is designed for manual operation. Automatic control can also be provided.
- Fuel can be LPG, Natural Gas or Propane for gas fired burners and HSD, LDO or Kerosene for Oil Fired Burners.
- It is suitably controlled by PID type controllers for automatic burners and by operating valve train for manual burners in order to achieve complete combustion.
- Combustion air is fan blown, requiring 380/440 v, 50 hz, 3 phase electrical supply.
- Flame supervision is by flame relay and U.V. flame sensor.
- Ignition is achieved by direct spark ignition transformer and fitted spark probe.